This can cause the valve spindle to seize. It often becomes stiff to turn at first and the valve may give intermittent problems. Eventually, the spindle may become so stiff that the valve motor cannot turn it at all.

Honeywell Home V4043H1056/U 2 Port Motorised Valve - Screwfix

Honeywell say that the manual lever located on the end of the powerhead is not a position indicator and should be used used for filling the system and for draining down only. On each product, under the specification tab, you will find more information on the guarantee or Warranty.Motorised valves are often fitted in tight spaces with limited visibility so note the orientation of the powerhead.

Honeywell Motorised Valves | Central Heating | Screwfix Honeywell Motorised Valves | Central Heating | Screwfix

This banging occurs due to air in the pipes. If I goto the loft and bleed the top-most valve the banging will go away. I can then use the HW again but I end up having the same problem." The Honeywell V4073A 3-port valve has five wires. These are blue, green/yellow, white, grey and orange. Note that the grey and orange wires are used differently from the grey and orange wires of the 2-port valve! In larger properties, 28mm valves may be used (the 5-wire 3-port V4073A1088 and the 6-wire 2-port V4043H1106). The 28mm V4043H1106 2-port zone valve has a6 th wire, coloured white. This white wire might not be used. In that case it should be made safe electrically. A programmer and room thermostat (stat) are used to control heating times and room air temperatures. The programmer and room stat may be combined into a single programmable room stat. Inside a Honeywell V4073A 3-port motorised valve showing the rubber ball which closes one or other port, never both.Whereas the internal electrics of the 2-port valve are quite simple, the internal electrical controls of the V4073A mid-position valve are more complex. When using two 2-port valves, the control system may be known as a Sundial S Plan system or a Honeywell S Plan system. I'm assuming that you've got no hot water due to the overheat malfunction - in which case there's nothing to stop you hooking the valve open permanently if this resolves the banging (and simultaneously getting you some hot water) until we determine why the valve isn't opening. IF it is a faulty valve, these aren't difficult to replace. V4043H1106 is a 2 port, 28mm compression, 6-wire, normally-closed zone valve with an auxiliary end switch

Motorised Valves | Honeywell | Zone Valves | Toolstation Motorised Valves | Honeywell | Zone Valves | Toolstation

Honeywell V4043H1056 22mm 2-port zone valves have five wires: green/yellow is Earth, blue is Neutral, brown is Live (or Line) to the motor, grey and orange are connected to the end switch and form part of a separate circuit. If, for example, the heating valve is failing in this way, you will get heat round the radiators while the cylinder hot water is being heated too. When the cylinder is up to temperature, the hot water motorised valve closes and no longer tells the boiler to fire, so the heating now stops too. Correct. I've not really got access to hot water. I say not really, as the boiler will run for ~10 mins, then the overheat light will come on, and then banging will occur in the pipes. This banging occurs due to air in the pipes. If I goto the loft and bleed the top-most valve the banging will go away. I can then use the HW again but I end up having the same problem.When a V4073A mid-position valve is set up in a Y-Plan configuration and Hot Water is called for, power to the boiler is provided directly from the cylinder thermostat. The valve is not energised. If the property uses a combi boiler (rather than a heat-only boiler) the boiler will usually contain a diverter valve. In small properties there may be no other motorised valves. As Boilers and radiators are installed by third parties, they do have to install in compliance with regulations and manufacturer standards to get the full benefit of the warranty. With the powerhead cover removed you also have access to the screw which retains the motor. The motor can, if necessary, be removed without disconnecting the powerhead from the valve body.